How do I set up the PenMount WinCE Driver to only use four point calibration?
This function is only supported in PenMount WinCE Standard driver V3.0 or later, please refer to Readme.txt in "Driver" folder.
(Please modify PMSer.reg file in "Driver" folder for the RS-232 interface, in case of USB interface please modify PM2Usb.reg file. Stylus uses MS embedded position software, so it is not supported)
[HKEY_LOCAL_MACHINESoftwarePenMountCalibrate]
"NoCal16"=dword:0 ====> When set to 0, standard calibration and advanced 9 and 16 point calibration are available
"NoCal16"=dword:1 ====> When set to 1, standard calibration and advanced 9 point calibration are available, 16 point calibration is not.
"DefaultCalib"=dword:9 ====> When set to 9, after calibration is started, users will not be able to choose number of calibration points, advanced 9 point calibration will be automatically selected.
0 stands for standard calibration, 4 stands for 4 point advanced calibration, 9 stands for 9 point advanced calibration, 16 stands for 16 point advanced calibration